KORE Insulated Foundation System Ireland
Foundation Overview
The KORE insulated foundation system is an NSAI certified EPS raft foundation that wraps your entire home footprint in continuous thermal insulation. By completely eliminating the critical wall to floor cold bridge, it delivers U values as low as 0.10 W/m²K for modern ICF and low energy Irish residential builds.
KORE foundation system
The KORE foundation system is an engineered modern method of substructure construction designed and manufactured in Ireland to eliminate heat loss through the ground floor of residential and commercial buildings. Traditional Irish building foundations rely on concrete strip footings poured into subsoil trenches, topped by rising blockwork walls and a concrete subfloor slab. In that conventional configuration, cold external ground temperatures bypass floor insulation sheets through the solid block rising walls, creating an uninsulated thermal bridge around the entire perimeter of the building.
The KORE system completely re-engineers this foundation junction by encasing the entire reinforced concrete slab and edge beams in custom-manufactured, high-density expanded polystyrene (KORE EPS). The system consists of interlocking precision-cut EPS profile sheets, perimeter L-shaped ring beam edge forms, and internal infill blocks. When assembled on site over compacted blinding, the KORE components create an impervious insulated trough. Reinforced steel cages and mesh are positioned inside the trough, and ready-mix concrete is poured directly into the insulated mould in a single monolithic placement.
Holding full NSAI Agrément Certificate 06/0268, the system is fully certified under Irish Building Regulations for structural load-bearing performance, ground moisture resistance, and extreme thermal efficiency. Because the concrete slab is insulated on its underside and around all vertical perimeter edges, the slab itself becomes part of the heated internal envelope of the home. This turns your concrete floor into a massive thermal reservoir, making it the perfect foundation solution for low-temperature underfloor heating systems and air-to-water heat pumps.
By using custom-graded EPS 100 for internal floor slab infill zones and ultra-high-density EPS 300 under load-bearing perimeter edge beams and internal structural load lines, the foundation supports multi-storey residential loads without risk of settlement or creep. The white expanded polystyrene material is completely inert, moisture resistant, and maintains its thermal performance intact for the entire design life of the building.
KORE insulated raft foundation cost
When calculating the cost of an insulated raft foundation in Ireland, self builders and quantity surveyors must assess the complete substructure package. While the raw expanded polystyrene profile components cost more than standard timber shuttering boards, an insulated raft drastically reduces site excavation depth, eliminates rising blockwork, cuts trench pumping labour, and shortens foundation timelines from weeks to days.
| House Slab Footprint | Typical Floor Area | KORE Profile Supply | Complete Installed Cost | Target U Value |
|---|---|---|---|---|
| Bungalow / Single Storey | 150 m² (1,615 sq ft) | €9,500 to €12,500 | €21,000 to €27,000 | 0.10 W/m²K |
| Two Storey Family Home | 100 m² footprint (200 m² total) | €7,200 to €9,800 | €16,000 to €21,000 | 0.10 W/m²K |
| Large Detached Self Build | 160 m² footprint (320 m² total) | €11,000 to €14,500 | €24,000 to €31,000 | 0.09 W/m²K |
On average, the fully installed cost of a KORE insulated foundation ranges between €130 and €180 per square metre of slab area. This figure includes site survey, engineered profile layout, steel rebar mesh and edge beam reinforcement, perimeter shuttering support, pump hire, concrete placement, and power-float finishing.
Self builders also achieve major indirect cost reductions: ground excavation requires only a shallow scrape rather than deep perimeter foundation trenches, reducing site muck-away disposal fees by thousands of euros. Furthermore, eliminating the traditional four-week curing cycle between strip footings and rising walls allows structural wall contractors to commence erection immediately after slab cure.
KORE foundation details
Engineering a successful KORE foundation requires strict adherence to manufacturer detail drawings and structural engineer specifications. Below is an engineering description of the multi-layered substructure detail:
KORE ICF.L02 Engineering Specification
Official detail drawings for 75mm outer EPS Insulated Concrete Formwork (ICF)
Sub-base Preparation: 30mm to 50mm T3 Fine Aggregate Blinding laid on a minimum 200mm T2 Unbound Granular Fill over T1 Structural hardcore, fully compacted in accordance with Irish standard S.R.21-Annex E: 2016.
Perimeter Land Drainage: Minimum 100mm diameter perforated land drain set in a washed stone trench at least 500mm wide around the entire foundation perimeter.
Radon Gas Barrier & DPM: Heavy-duty radon membrane extended at least 1.0 metre beyond the outer profile edge and returned up the vertical face of the profile to act as a permanent damp proof membrane following the concrete pour.
Vertical Profile Protection: Durable cementitious fibre board to EN 12476 bonded to the vertical face of the KORE outer profile using low-expansion polyurethane foam.
Dual-Density Engineered Insulation: KORE EPS300 with compressive strength not less than 300 kPa at 10% compression placed under outer ICF wall lines, perimeter edge beams, and load-bearing steps. KORE EPS100 with compressive strength not less than 100 kPa placed in interior floor beds.
Structural Concrete Slab: 150mm reinforced concrete slab with rebar and mesh placed to chartered structural engineer specification.
ICF Wall Junction: 75mm outer EPS Insulated Concrete Formwork wall erected directly over the damp proof course on the raft edge.
- · Compressive strength: 300 kPa at 10% compression
- · Manufacturing: EN 13163 under ISO 9001 and ISO 14001
- · Total GWP: verified under 120.0 kgCO₂eq/m³ (Stages A1 to A3)
- · Net Zero pathway: third-party validated to ISO 14068-1:2023
- · Location: perimeter ring beams, ICF wall footings, and point loads
- · Compressive strength: 100 kPa at 10% compression
- · Total GWP: verified under 60.4 kgCO₂eq/m³ (Stages A1 to A3)
- · Environmental: 100% CFC and HCFC free with verified EPD
- · Fixings: interior U-Pins (never placed in bottom layer to protect radon barrier)
- · Location: central underfloor insulation bed (typically 300mm total EPS)
Verified Embodied Carbon Comparison (EPD to EN 15804)
Based on a typical 3-bedroom semi-detached Irish home (perimeter to area ratio 0.4) achieving a floor U-value of 0.15 W/m²K:
| Floor Insulation Type | Thickness | Compressive Strength | Thermal Conductivity | Embodied Carbon (A1 to A3) |
|---|---|---|---|---|
| KORE EPS70 Silver | 160mm | 70 kPa | 0.031 W/mK | 431 kgCO₂eq |
| KORE EPS100 Silver | 160mm | 100 kPa | 0.031 W/mK | 575 kgCO₂eq |
| Standard PIR Insulation | 120mm | 140 kPa | 0.022 W/mK | 984 kgCO₂eq |
KORE EPS reduces upfront embodied carbon by over 56% compared to PIR insulation boards, supporting circular construction standards under the RIAI Climate Action Plan and RIBA 2030 Climate Challenge.
Thermal Energy Storage & Underfloor Heating Performance
According to official KORE thermal dynamic analysis (Drawing ICF.L02. 15), casting a 150mm reinforced concrete slab directly on the KORE insulated foundation transforms the floor into a massive thermal flywheel. An operational heat cycle maintains indoor comfort for 149 hours and 40 minutes, compared to only 62 hours and 10 minutes in a traditional foundation with a 75mm screed. This enables low-temperature heat pumps to run during off-peak night electricity tariffs while radiating gentle, consistent warmth all day.
Standard Detail Drawing Reference (Series ICF.L02)
Every detail is engineered to satisfy the rigorous requirements of the Irish Building Control Management System (BCMS). The damp proof membrane and radon gas barrier are positioned either beneath the EPS insulation sheets or directly above them, depending on the site-specific ground gas risk assessment. All underground drainage soil stacks, water supply ducts, electrical incoming pipes, and heat pump geothermal loops pass vertically through the EPS profiles sealed with heavy-duty EPDM pipe sleeves and airtight collars before the concrete pour.
Insulated raft foundation vs strip foundation
Choosing between a modern insulated raft and traditional strip footings affects your building project across three major dimensions: thermal efficiency, structural performance on challenging soil, and total on-site labour duration.
| Comparison Factor | KORE Insulated Raft Foundation | Traditional Concrete Strip Footings |
|---|---|---|
| Thermal Bridging (Y-Value) | Zero perimeter cold bridge; achieves Psi values under 0.01 W/mK | Severe thermal bridge through rising concrete blocks into cold ground |
| Floor U Value Achievement | 0.08 to 0.10 W/m²K with continuous EPS core | Typically 0.15 to 0.18 W/m²K with discontinuous PIR boards |
| Ground Bearing Requirements | Spreads structural weight uniformly over entire footprint (low load density) | Concentrates heavy structural loads onto narrow trenches (requires firmer soil) |
| Excavation Depth & Spoil | Shallow scrape (typically 300mm to 500mm), reducing muck-away costs | Deep trenches (typically 900mm to 1200mm), generating massive spoil volumes |
| Build Program Duration | Installed and poured in 3 to 5 days ready for wall construction | 3 to 4 weeks requiring multiple blocklaying and curing phases |
On poor bearing ground such as peat margins, alluvial silt, or urban reclaimed ground, a traditional strip foundation frequently fails soil tests, forcing the developer into expensive ground improvement, piling rigs, or deep mass-concrete trenches. An insulated raft behaves like an engineered floating pontoon: by distributing structural weight across hundreds of square metres, ground bearing pressure is lowered to gentle levels that most Irish subsoils comfortably accommodate without differential settlement.
ICF foundations on a KORE raft
When building an ICF construction project or private ICF house, pairing the wall system with a KORE insulated raft foundation creates the ultimate low energy building envelope available in modern European construction.
In conventional construction, the interface between the foundation slab and the exterior wall is the primary failure point for thermal performance and airtightness. With an ICF wall sitting directly on a KORE raft, the EPS perimeter upstand of the foundation connects directly to the EPS exterior skin of the ICF formwork. This creates one completely unbroken insulated boundary that wraps the building continuously from the subsoil sand blinding right up to the eaves of the roof.
Starter rebar dowels are cast into the KORE edge beam during the concrete pour at exact centres matching your chosen ICF block system. When our installation crew commences wall stacking, the first course of hollow EPS blocks slips effortlessly over the starter dowels and locks into place with adhesive foam. Structural continuity between the monolithic foundation raft and the vertical concrete wall core is permanent and indestructible.
This unified system eliminates all linear thermal bridging at the critical foundation wall junction. In thermal modelling software (such as Therm or Psi-Value calculators), the junction records a linear thermal transmittance (Psi value) under 0.01 W/mK, effectively rendering thermal bypass negligible. For self builders pursuing Passive House certification or A1 BER status, this foundation detail provides the indispensable engineering foundation for long-term comfort and energy savings.
Frequently Asked Questions About KORE Insulated Foundations
What is the KORE insulated foundation system and how does it work?
The KORE insulated foundation system is an engineered, NSAI certified precision-cut expanded polystyrene (EPS) raft foundation. It wraps the entire building subfloor and perimeter ring beam in continuous insulation, completely eliminating the thermal bridge at the wall-to-floor junction and achieving floor U values as low as 0.10 W/m²K.
How much does a KORE insulated raft foundation cost per m² in Ireland?
A KORE insulated raft foundation typically costs between €130 and €180 per square metre of ground floor slab area, including precision EPS components, site engineering assembly, structural steel reinforcement, concrete supply, and placement. Total costs vary based on ground bearing capacity and site excavation.
Why is a KORE insulated raft superior to traditional strip footings for ICF?
Traditional strip foundations create a severe repeating cold bridge where inner leaf blocks meet the subfloor rising walls. A KORE raft creates one monolithic, unbroken insulated tub. When combined with ICF walls, the EPS foundation insulation connects directly with the wall EPS, creating an unbroken thermal boundary.
Can the KORE system be installed on sites with poor soil bearing capacity?
Yes. Because an insulated raft foundation distributes the entire weight of the house across a broad, continuous footprint, it drastically reduces ground bearing pressures compared to concentrated strip footings. This makes it ideal for soft soils, peat margins, and brownfield infill sites without requiring expensive piling.
Do I need a structural engineer for a KORE insulated foundation?
Yes. A chartered structural engineer must review your site ground investigation report, approve sub-base compaction, design the reinforced steel mesh and edge beam rebar cages, and sign off the concrete placement for building regulations compliance.
How fast can an Isotherm crew install a KORE foundation profile?
Once site excavation and hard-core blinding are certified, an Isotherm installation crew assembles the precision interlocking KORE profile components in two to three days, preparing the ground for immediate steel placement and concrete pour.
How is radon barrier gas protection integrated into the KORE raft?
An NSAI approved 1200 gauge radon barrier membrane is installed directly over the blinding sand beneath the KORE EPS sheets, or laid continuously over the base insulation before concrete placement. All pipe penetrations are sealed with proprietary top-hat collars and radon tape.
What compressive strength concrete is specified for an insulated raft?
Structural engineers typically specify C28/35 or C30/37 ready-mix concrete with a designated slump class S3 or S4, poured with a boom pump and consolidated using mechanical pencil pokers to avoid displacing reinforcement steel or EPS profiles.
Related Foundation and ICF Resources
Continue exploring modern substructure and wall engineering:
Get an Engineered KORE Foundation Quote
Send us your ground investigation report, site layout, and structural drawings. Our foundation engineering team in Inchicore will calculate profile layouts, rebar quantities, and deliver an itemized fixed price quotation.